Skip to content

C.LP-15/200

From the thicknessGAUGE C.LP series

thicknessGAUGE C.LP: sensors and measurement devices by Micro-Epsilon for measurement & 3d systems.

System accuracy
1.2 µm
Download the datasheet (opens in a new tab) Visit the Micro-Epsilon site (opens in a new tab)

Technical specification

Every engineering figure, laid out to scan quickly

Technical specification for C.LP-15/200
System accuracy 1.2 µm
Resolution 0.2 µm
Measuring rate 100 Hz
System calibration type Automatic
Maximum material width 200 mm
Storage temperature -20–65 °C
Operating temperature 5–45 °C
Humidity 5–95 %RH
Measuring range 15 mm
Technical specification details 15 mm thickness measuring range; 200 mm named measuring width.
Laser class 2M
Maximum travel 380 mm
Operating range 144 mm
Repeatability reference Repeatability not stated in the reviewed official source.
Sampling rate reference Official maximum measurement or output rate: 100 Hz.

Values by configuration

These values differ with the controller or interface the sensor is used with. Each row applies to one configuration only; check the configuration in the system builder or with us.

Interface options depending on system components PROFINET
Interface options depending on system components EtherNet/IP
Interfaces Ethernet
Interfaces PROFINET
Interfaces EtherCAT
Outputs and interfaces OPC UA
Outputs and interfaces EtherCAT (additional bus terminal required)
Outputs and interfaces Analog 0-10V
Outputs and interfaces Digital I/O
Protection class (DIN EN 60529) IP40
Protection class (DIN EN 60529) IP54
Request a quote for this product

Compatible accessories

Complementary products

The industries we serve

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words