Skip to content

turboSPEED DZ140 Rotational speed

turboSPEED DZ140: sensors and measurement devices by Micro-Epsilon for rotational speed.

Download the datasheet (opens in a new tab) This series on the Micro-Epsilon site (opens in a new tab)

Shared technical specifications for the series

Properties every model in the series has. What differs is in the models table below.

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of turboSPEED DZ140
Cable length 0.5–0.8 m
Operating temperature -50–235 °C
Cable diameter 3.5–6 mm
Storage temperature -40–235 °C

Models in the series

One column per model: what differs between the models of the series.

Models of turboSPEED DZ140 compared by parameter
Parameter DS 05(03) DS 05(04) DS 05(07) DS 05(14) DS 05(15) DS 1 DS 1(04) DS 1/T
Protection class (DIN EN 60529) IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65
Linearity reference Official DZ140 controller linearity is better than ±0.2% FSO over the configured 200 to 400,000 rpm measuring range. Official DZ140 controller linearity is better than ±0.2% FSO over the configured 200 to 400,000 rpm measuring range. Official DZ140 controller linearity is better than ±0.2% FSO over the configured 200 to 400,000 rpm measuring range. Official DZ140 controller linearity is better than ±0.2% FSO over the configured 200 to 400,000 rpm measuring range. Official DZ140 controller linearity is better than ±0.2% FSO over the configured 200 to 400,000 rpm measuring range. Official DZ140 controller linearity is better than ±0.2% FSO over the configured 200 to 400,000 rpm measuring range. Official DZ140 controller linearity is better than ±0.2% FSO over the configured 200 to 400,000 rpm measuring range. Official DZ140 controller linearity is better than ±0.2% FSO over the configured 200 to 400,000 rpm measuring range.
Sensor shielding "shielded" "shielded" "shielded" "shielded" "shielded" "shielded" "shielded" "shielded"
Technical specification details 200 to 400,000 rpm; target gap up to 2.2 mm; curved clamp-mount housing; sensor operation to 200 °C. 200 to 400,000 rpm; target gap up to 2.2 mm; straight clamp-mount housing; sensor operation to 200 °C. 200 to 400,000 rpm; target gap up to 2.2 mm; M5 screw connection; sensor operation to 200 °C. 200 to 400,000 rpm; target gap up to 2.2 mm; extended M5 screw connection; sensor operation to 200 °C. 200 to 400,000 rpm; target gap up to 2.2 mm; compact M5 screw connection; sensor operation to 200 °C. 200 to 400,000 rpm; target gap up to 2.2 mm; M5 x 0.5 screw connection; sensor operation to 235 °C. 200 to 400,000 rpm; target gap up to 2.2 mm; M5 x 0.5 connection with stainless-steel protective hose; sensor operation to 235 °C. 200 to 400,000 rpm; target gap up to 2.2 mm; triaxial high-temperature connection; 285 °C short-term; sensor operation to 235 °C.
Cable length 0.5 m 0.5 m 0.5 m 0.5 m 0.5 m 0.75 m 0.8 m 0.8 m
Sensor mechanical feature "curved housing" Not specified Not specified "housing length 42.5 mm" Not specified Not specified "protective hose (stainless steel)" Not specified
Non-contact speed measurement True True True True True True True True
Cable connector type "BNC coaxial" "BNC coaxial" "BNC coaxial" "BNC coaxial" "BNC coaxial" "BNC coaxial" "BNC coaxial" "BNC triaxial"
Accuracy (% FSO) 0.2 % 0.2 % 0.2 % 0.2 % 0.2 % 0.2 % 0.2 % 0.2 %
Sampling rate reference The controller supplies one TTL pulse per blade or one pulse per revolution plus a 0 to 5 V speed output; no unsupported scalar update-rate claim is added. The controller supplies one TTL pulse per blade or one pulse per revolution plus a 0 to 5 V speed output; no unsupported scalar update-rate claim is added. The controller supplies one TTL pulse per blade or one pulse per revolution plus a 0 to 5 V speed output; no unsupported scalar update-rate claim is added. The controller supplies one TTL pulse per blade or one pulse per revolution plus a 0 to 5 V speed output; no unsupported scalar update-rate claim is added. The controller supplies one TTL pulse per blade or one pulse per revolution plus a 0 to 5 V speed output; no unsupported scalar update-rate claim is added. The controller supplies one TTL pulse per blade or one pulse per revolution plus a 0 to 5 V speed output; no unsupported scalar update-rate claim is added. The controller supplies one TTL pulse per blade or one pulse per revolution plus a 0 to 5 V speed output; no unsupported scalar update-rate claim is added. The controller supplies one TTL pulse per blade or one pulse per revolution plus a 0 to 5 V speed output; no unsupported scalar update-rate claim is added.
Operating temperature -50–200 °C -40–200 °C -40–200 °C -40–200 °C -50–200 °C -40–235 °C -40–235 °C -50–200 °C
Sensor mounting "Clamping/adapter" "Clamping/adapter" "Screw connection (M5)" "Screw connection (M5)" "Screw connection (M5)" "Screw connection (M5)" "Screw connection (M5)" "Screw connection (M5)"
Cable diameter 3.5 mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 3.5 mm 6 mm Not specified
Sensor cable length tolerance 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15
Outputs and interfaces Analog 0-10V Digital I/O Analog 0-10V Analog 0-10V Digital I/O Analog 0-10V Digital I/O Analog 0-10V
Rotational speed range 200–400000 rpm 200–400000 rpm 200–400000 rpm 200–400000 rpm 200–400000 rpm 200–400000 rpm 200–400000 rpm 200–400000 rpm
Maximum rotational speed 400000 rpm 400000 rpm 400000 rpm 400000 rpm 400000 rpm 400000 rpm 400000 rpm 400000 rpm
Storage temperature -40–200 °C -40–200 °C -40–200 °C -40–200 °C -40–200 °C -40–235 °C -40–235 °C -40–235 °C
Repeatability reference The official data sheet does not publish a separate scalar system repeatability value. The official data sheet does not publish a separate scalar system repeatability value. The official data sheet does not publish a separate scalar system repeatability value. The official data sheet does not publish a separate scalar system repeatability value. The official data sheet does not publish a separate scalar system repeatability value. The official data sheet does not publish a separate scalar system repeatability value. The official data sheet does not publish a separate scalar system repeatability value. The official data sheet does not publish a separate scalar system repeatability value.
Working distance 0–2.2 mm 0–2.2 mm 0–2.2 mm 0–2.2 mm 0–2.2 mm 0–2.2 mm 0–2.2 mm 0–2.2 mm
Triax cable diameter (as described) Not specified Not specified Not specified Not specified Not specified Not specified Not specified 5
Sensor maximum short-term temperature Not specified Not specified Not specified Not specified Not specified Not specified Not specified 285
Sensor cable diameter (drawing) Not specified Not specified Not specified Not specified Not specified Not specified Not specified 4.5
Status Active Active Active Active Active Active Active Active
Datasheet PDF — DS 05(03) (opens in a new tab) PDF — DS 05(04) (opens in a new tab) PDF — DS 05(07) (opens in a new tab) PDF — DS 05(14) (opens in a new tab) PDF — DS 05(15) (opens in a new tab) PDF — DS 1 (opens in a new tab) PDF — DS 1(04) (opens in a new tab) PDF — DS 1/T (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Aluminium and titanium blades are specified; this does not establish compatibility with other materials.

The stated rating applies to the sensor; it does not establish the controller or complete-system temperature rating.

The page lists 200–400000 rpm. Suitability also requires blade-material, clearance and head-installation checks.

Yes. It describes a miniature controller for engine-compartment integration and a head installed at the turbocharger. Match connections and each component’s environment.

No. Also define supported blade material, sensor clearance, speed and operating temperature. Together these determine the measurement configuration.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words