Technical specification for Z7A
Ordering options and constraints K-Z7A_ — capacity: 1102.31 lb, 2204.62 lb, 4409.24 lb, 11023.11 lb, 22046.22 lb; accuracy_class: D1, C3; minimum_verification_interval_vmin: 178.5 g, 357 g, 714 g, 1785 g, 3570 g, 200 g, 500 g, 1000 g; constraints: []

Range across models

The span covered by the models of the series together — not the range of each model.

Range across the models of Z7A
Operating temperature -30–70 °C
Protection class (DIN EN 60529) IP67
Weight 2.3 kg
Force range 0–19613.27668 N
Nominal temperature range -10–40 °C
Mounting torque 135 Nm
Storage temperature -50–85 °C
Maximum excitation voltage 18 V
Bridge sensitivity 2 mV/V
Accuracy (% FSO) 1–3 %
Nominal force capacity 4903.319169–98066.47234 N
ADC sampling rate 19200–40000 samples/s

Models in the series

One column per model: what differs between the models of the series.

Models of Z7A compared by parameter
Parameter 1-Z7AC3/10T 1-Z7AC3/2T 1-Z7AC3/5T 1-Z7AD1/10T 1-Z7AD1/1T 1-Z7AD1/2T 1-Z7AD1/500KG 1-Z7AD1/5T K-Z7A_ · 1102.31 lb K-Z7A_ · 11023.11 lb K-Z7A_ · 2204.62 lb K-Z7A_ · 22046.22 lb K-Z7A_ · 4409.24 lb Z7A-0p5t Z7A-10t Z7A-1t Z7A-2t Z7A-5t
Operating temperature -30–70 °C -30–70 °C -30–70 °C -30–70 °C -30–70 °C -30–70 °C -30–70 °C -30–70 °C Not specified Not specified Not specified Not specified Not specified -30–70 °C -30–70 °C -30–70 °C -30–70 °C -30–70 °C
Protection class (DIN EN 60529) IP67 IP67 IP67 IP67 IP67 IP67 IP67 IP67 Not specified Not specified Not specified Not specified Not specified IP67 IP67 IP67 IP67 IP67
Weight 8 kg 2.3 kg 5 kg 8 kg 2.3 kg 2.3 kg 2.3 kg 5 kg Not specified Not specified Not specified Not specified Not specified 2.3 kg 8 kg 2.3 kg 2.3 kg 5 kg
Force range 0–98066.5 N 0–19613.3 N 0–49033.25 N 0–98066.5 N 0–9806.65 N 0–19613.3 N 0–4903.325 N 0–49033.25 N Not specified Not specified Not specified Not specified Not specified 0–4903.325 N 0–98066.5 N 0–9806.65 N 0–19613.3 N 0–49033.25 N
Nominal temperature range -10–40 °C -10–40 °C -10–40 °C -10–40 °C -10–40 °C -10–40 °C -10–40 °C -10–40 °C Not specified Not specified Not specified Not specified Not specified -10–40 °C -10–40 °C -10–40 °C -10–40 °C -10–40 °C
Mounting torque 1150 Nm 135 Nm 660 Nm 1150 Nm 135 Nm 135 Nm 135 Nm 660 Nm Not specified Not specified Not specified Not specified Not specified 135 Nm 1150 Nm 135 Nm 135 Nm 660 Nm
Storage temperature -50–85 °C -50–85 °C -50–85 °C -50–85 °C -50–85 °C -50–85 °C -50–85 °C -50–85 °C Not specified Not specified Not specified Not specified Not specified -50–85 °C -50–85 °C -50–85 °C -50–85 °C -50–85 °C
Maximum excitation voltage 18 V 18 V 18 V 18 V 18 V 18 V 18 V 18 V Not specified Not specified Not specified Not specified Not specified 18 V 18 V 18 V 18 V 18 V
Bridge sensitivity 2 mV/V 2 mV/V 2 mV/V 2 mV/V 2 mV/V 2 mV/V 2 mV/V 2 mV/V Not specified Not specified Not specified Not specified Not specified 2 mV/V 2 mV/V 2 mV/V 2 mV/V 2 mV/V
Outputs and interfaces Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Not specified Not specified Not specified Not specified Not specified Analog 0-10V Digital I/O Digital I/O Digital I/O Digital I/O
Input resistance 350 ohm 350 ohm 350 ohm 350 ohm 350 ohm 350 ohm 350 ohm 350 ohm Not specified Not specified Not specified Not specified Not specified 350 ohm 350 ohm 350 ohm 350 ohm 350 ohm
Minimum verification interval ratio Y 10000 10000 10000 2800 2800 2800 2800 2800 Not specified Not specified Not specified Not specified Not specified 2800 10000 2800 2800 2800
Maximum load cell verification intervals 3000 3000 3000 1000 1000 1000 1000 1000 Not specified Not specified Not specified Not specified Not specified 1000 1000 1000 1000 3000
Accuracy (% FSO) 3 % 3 % 3 % 1 % 1 % 1 % 1 % 1 % Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Permissible dynamic load amplitude (% of Emax) 70 70 70 70 70 70 70 70 Not specified Not specified Not specified Not specified Not specified 70 70 70 70 70
Safe load limit (% of Emax) 150% of Emax 150% of Emax 150% of Emax 150% of Emax 150% of Emax 150% of Emax 150% of Emax 150% of Emax Not specified Not specified Not specified Not specified Not specified 150% of Emax 150% of Emax 150% of Emax 150% of Emax 150% of Emax
Minimum verification interval (% of Emax) 0.01 0.01 0.01 0.0357 0.0357 0.0357 0.0357 0.0357 Not specified Not specified Not specified Not specified Not specified 0.0357 0.01 0.0357 0.0357 0.01
Accuracy class (OIML R60) C3 C3 C3 D1 D1 D1 D1 D1 Not specified Not specified Not specified Not specified Not specified D1 C3 D1 C3 C3
Breaking load (as specified) 300 300 300 300 300 300 300 300 Not specified Not specified Not specified Not specified Not specified 300 300 300 300 300
Sampling rate limited by system readout True True True True True True True True Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Nominal displacement approximately 0.7 mm approximately 0.35 mm approximately 0.45 mm approximately 0.7 mm approximately 0.3 mm approximately 0.35 mm approximately 0.25 mm approximately 0.45 mm Not specified Not specified Not specified Not specified Not specified approximately 0.25 mm approximately 0.7 mm approximately 0.3 mm approximately 0.35 mm approximately 0.45 mm
Linearity reference Official family-table accuracy class: C3; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: C3; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: C3; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: D1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: D1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: D1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: D1; retained as a class, not converted to overall installed-chain accuracy. Official family-table accuracy class: D1; retained as a class, not converted to overall installed-chain accuracy. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Technical specification details Maximum capacity: 22046 lb; Accuracy class: C3; Minimum verification interval (Vmin): 1000 g Maximum capacity: 4409 lb; Accuracy class: C3; Minimum verification interval (Vmin): 200 g Maximum capacity: 11023 lb; Accuracy class: C3; Minimum verification interval (Vmin): 500 g Maximum capacity: 22046 lb; Accuracy class: D1; Minimum verification interval (Vmin): 3570 g Maximum capacity: 2205 lb; Accuracy class: D1; Minimum verification interval (Vmin): 100 g Maximum capacity: 4409 lb; Accuracy class: D1; Minimum verification interval (Vmin): 714 g Maximum capacity: 1102 lb; Accuracy class: D1; Minimum verification interval (Vmin): 178.5 g Maximum capacity: 11023 lb; Accuracy class: D1; Minimum verification interval (Vmin): 1785 g Not specified Not specified Not specified Not specified Not specified 0.5 t rated capacity = 4.9033 kN (500 kg mass equivalent at standard gravity); compression 10 t rated capacity = 98.0665 kN (10 t mass equivalent at standard gravity); compression 1 t rated capacity = 9.8067 kN (1 t mass equivalent at standard gravity); compression 2 t rated capacity = 19.6133 kN (2 t mass equivalent at standard gravity); compression 5 t rated capacity = 49.0333 kN (5 t mass equivalent at standard gravity); compression
Repeatability reference Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Use the individual calibration certificate and installed-chain verification; no unsupported scalar repeatability is inferred. Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified
Sampling rate reference The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. The selected HBK conditioner, filter and DAQ determine the digital sample rate. Not specified Not specified Not specified Not specified Not specified ClipX fixed internal sampling rate; verify the configured filter and usable output bandwidth MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth MX840B maximum per-channel sample rate; sensor mechanics and filter settings can reduce usable bandwidth
Selected configuration options Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 1102.31 lb nominal force capacity 11023.11 lb nominal force capacity 2204.62 lb nominal force capacity 22046.22 lb nominal force capacity 4409.24 lb nominal force capacity Not specified Not specified Not specified Not specified Not specified
Nominal force capacity Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 4903.319169 N 49033.23617 N 9806.638338 N 98066.47234 N 19613.27668 N Not specified Not specified Not specified Not specified Not specified
Published accuracy class Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Official family-table accuracy class: D1, C3 Official family-table accuracy class: D1, C3 Official family-table accuracy class: D1, C3 Official family-table accuracy class: D1, C3 Official family-table accuracy class: D1, C3 Not specified Not specified Not specified Not specified Not specified
ADC sampling rate Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified 19200 samples/s 19200 samples/s 40000 samples/s 40000 samples/s 40000 samples/s
Interfaces Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Not specified Ethernet PROFINET EtherCAT Ethernet Ethernet
Status Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active
Datasheet PDF — K-Z7A_ · 1102.31 lb (opens in a new tab) PDF — K-Z7A_ · 11023.11 lb (opens in a new tab) PDF — K-Z7A_ · 2204.62 lb (opens in a new tab) PDF — K-Z7A_ · 22046.22 lb (opens in a new tab) PDF — K-Z7A_ · 4409.24 lb (opens in a new tab)

The industries we serve

Frequently asked questions

Answers to the most common questions about our products and services

Z7A offers 0.5, 1, 2, 5 and 10 t maximum capacities. Check threads, dimensions, deflection and permissible side loads for the particular capacity.

No. The D1 table covers 0.5–10 t, while C3 lists 2, 5 and 10 t. D1 and C3 correspond to 1000 and 3000 verification intervals respectively, not sampling rates.

The datasheet specifies six-wire connection and 2 mV/V nominal sensitivity. Use a suitable excited strain-gauge bridge input and preserve the cell data in system calibration.

No. Ingress protection is IP67, but the measuring body is specified as galvanized steel. Cable-gland material is specified separately. Do not infer body material from IP rating.

Yes. The higher parenthesized side-load values require stops preventing cell-base movement, and the manufacturer warns of significant error effects under that condition. ZEL and ZPL supports are listed as separately ordered accessories.

Didn't find the answer you were looking for?

Talk to an expert

More information

Get a quote or advice

Tell us what you need and an engineer will come back to you.

Request a quote for this product
What would you like to ask for?

Email or phone — one of them is enough

Email or phone — one of them is enough

0 of 500 words